lu.ca/calc/Materials

Material library

published, citedtypical valueedited · no citationedited · your sourceadded · no citation

How to read this library

  • Minimum values (“min”) come from the material standard or specification and are what design codes use. Typical values (“typ”) are producer or handbook data for orientation only; they are shown in italics.
  • Strength often depends on thickness or section size. The table shows the thinnest range; the detail panel lists every range the source gives.
  • Each number links to the source it was taken from. Sources marked “secondary” are compilations rather than the standard or a producer.
  • Edit any cell to use your own value. Edited and added numbers are flagged until you attach a source in the detail panel. Edits stay in this browser and feed the calculators; use Export to share them.
  • The limiting surface pressure pG under bolt heads comes from VDI 2230-1 Table A9 where a transcription could be verified; elsewhere the calculators fall back to the yield strength, which is conservative, and say so.