anchor in tension (stronger colour = more)breakout area of the governing modeDrag anchors, the plate and the member edges · double-click to add an anchor · Delete removes the selected one
Margins
every failure mode of the code, MS = resistance ÷ load − 1 with the code's partial factors in the resistance. Point at an icon to see the failure.Install
from the anchor's approvalCompare anchors
same layout and loadsCalculation
each mode with its clause and intermediate valuesSources and assumptions
Assumptions
- Anchor forces from a rigid plate on the concrete: the concrete takes compression only, the anchors tension only; shear is shared equally (none along a slot) and torsion by the polar moment. Or type the forces per anchor.
- The member is a slab or wall with straight edges; its thickness and the edges you set limit the failure bodies. Edge reinforcement and supplementary reinforcement only as ticked.
- Anchor values (resistances, k-factors, τ, ccr, hmin …) come from the anchor's European Technical Assessment (EN) or ICC-ES Evaluation Report (ACI); the reference designs use the values their sources print.
- ACI 318 is evaluated in its inch-pound edition, as the evaluation reports are written; results are shown in your units. f′c is capped at 10,000 psi for cast-in and 8000 psi for post-installed anchors, and λ is kept between 0.75 and 1.0, as Chapter 17 requires.
Sources
- EN 1992-4:2018. Eurocode 2 — Design of concrete structures — Part 4: Design of fastenings for use in concrete. CEN. Equations as cited per row. We don't hold a copy of the 2018 text: its equations are taken as Hilti's public PROFIS reports print them, and checked against its predecessor CEN/TS 1992-4-1 to -5:2009 wherever the method carried over.
- ACI 318-19. Building Code Requirements for Structural Concrete, Chapter 17 Anchoring to concrete. American Concrete Institute. Checked clause by clause against ACI 318-14 Chapter 17, which has the same equations under older numbers.
- EOTA TR 020 (2004) and TR 082 (2024) for fire, TR 045 (2013) for seismic actions, TR 054 (2026) for masonry, each named on the rows it is used for.
- Hilti PROFIS Engineering 3.0 calculation reports (public, files-ask.hilti.com) for the EN reference designs; Hilti North American Anchor Fastening Technical Guide, Ed. 17, §3.1.10 for the ACI ones. The engine's tests reproduce their intermediate values.
For design studies. Check against the anchor's approval and the full code before relying on it. Related: Base plate and anchor bolts · Bolt pattern, 3D · Thread engagement